Newsletter 18: Managing “Blue Smoke” and Gas-Phase VOCs Across Industries

In industrial operations, Blue Smoke is a challenging multi-phase emission consisting of condensed hydrocarbons, hydrogen sulfide (H₂S), and gas-phase Volatile Organic Compounds (VOCs). Prevalent in sectors ranging from asphalt and oil to rubber curing, plastic extrusion, and food processing, this visible emission presents a complex technical hurdle. Because these plumes combine submicron liquid droplets with odorous gas-phase pollutants, a nuanced, multi-stage control strategy is required to prevent odor complaints, eliminate employee exposure to H₂S and other odors, reduce opacity/visible emissions and meet regulatory standards.

The Physics of Blue Smoke: Why Standard Filtration Fails
Blue Smoke typically forms when high-temperature organic vapors (250°F–500°F) hit cooler ambient air, causing them to condense into a fine mist. These droplets are often submicron in size (0.1 to 1.0 microns), placing them in the most difficult range for traditional collection methods.

  • Filter Plugging Risk: In applications like asphalt or rubber manufacturing, these droplets are “sticky.” Traditional fiber-bed filters often “blind” or clog rapidly, leading to a spike in differential pressure and reduced face velocity at the source.
  • Persistent Odors: Even if the visible mist is captured, gas-phase VOCs and compounds like H₂S can pass through mechanical filters entirely, resulting in persistent odor complaints.

Here’s a comparative chart of common control technologies:

Comparative Analysis of Blue Smoke Removal Technologies

Case Study: Two-Stage Mitigation at an Asphalt Terminal
At a major asphalt terminal operating at 300°F, we paired the UHF® system with our CarbonPure Activated Carbon Adsorption system to solve persistent odor control issues, opacity and H₂S violations. This configuration provides a technical blueprint for managing dual-phase emissions:

  • Stage 1: Ultra High-Efficiency Filter (UHF®) System. To manage the condensed hydrocarbon phase, APC’s UHF® was installed. The UHF® unit is specifically designed to remove very fine, oily &/or sticky particulate such as condensed asphalt fumes.
  • Stage 2: CarbonPure Activated Carbon Adsorption System. With the oily Blue Smoke removed, the air stream entered APC’s activated carbon vessels. With APC’s UHF® protecting the carbon beds from fouling, these systems achieved 99.7% odor removal efficiency (reducing inlet levels from 1,247 O.U. to 4.3 O.U.).

The system’s success was confirmed during a slow winter period when the terminal briefly deactivated the units to save on utilities. Neighborhood odor complaints returned immediately, only ceasing once the system was restarted.

You can read more about this case study at the link below:

Case Study: APC’s Emission Control for an Asphalt Terminal

Case Study: APC's Emission Control for an Asphalt Terminal

Think one of our systems may be a good fit for your applications? Contact one of our engineers today or check out our website for more information.